    Anti-HDV

    For in-vitro qualitative detection of Hepatitis D virus infection in human serum or plasma

    Anti-HDV– Product Details

    For in-vitro qualitative detection of Hepatitis D virus infection in human serum or plasma
    • Product Name
      GBC HDV Ab
    • Specificity
      97.95%
    • Sensitivity
      100%
    • Format
      PLATE
    • Cat. No.
      4EHD001
    • Package Size
      96 TESTS / KIT
    • Substrate
      TMB
    • Method
      Directed Sandwich Principle
    • Principle
      Enzyme Linked Immunosorbent Assay
    • Shelf Life
      6 months
    • Sample
      100 ul
    • Total Time
      ~110 min
    • Certification
      TFDA

    Anti-HBs (Quantitative)

    For in vitro quantitative detection of Antibody to Hepatitis B surface antigen (Anti-HBs) in human serum or plasma.

    The test can be used prior and after hepatitis B vaccination to assess the immune status as well as an aid to diagnose and monitor infections by hepatitis B virus.

    Anti-HBs (Quantitative)– Product Details

    For in vitro quantitative detection of Antibody to Hepatitis B surface antigen (Anti-HBs) in human serum or plasma.The test can be used prior and after hepatitis B vaccination to assess the immune status as well as an aid to diagnose and monitor infections by hepatitis B virus.
    • Product Name
      ANTISURASE B-96 TMB II
    • Specificity
      99.52%
    • Sensitivity
      100%
    • Format
      PLATE
    • Cat. No.
      4SBE6
    • Package Size
      96 TESTS / KIT
    • Substrate
      TMB
    • Method
      Peroxidase conjugated
    • Principle
      Enzyme Linked Immunosorbent Assay
    • Shelf Life
      12 months
    • Sample
      50ul
    • Total Time
      ~90 min
    • Certification
      TFDA/CE

    LH (LUTEINIZING HORMONE)

    LH (LUTEINIZING HORMONE)– Product Details

    ...
    • test
      test

    GB HBV RealQuant® PCR Kit

    GB HBV RealQuant® PCR is an in vitro real time polymerase chain reaction (PCR) kit for the quantitation of Hepatitis B Virus (HBV) DNA in human plasma or serum from HBV-infected individuals.

    GB HBV RealQuant® PCR Kit– Product Details

    GB HBV RealQuant® PCR is an in vitro real time polymerase chain reaction (PCR) kit for the quantitation of Hepatitis B Virus (HBV) DNA in human plasma or serum from HBV-infected individuals.
    • Product Name
      GB HBV RealQuant® PCR
    • Platform
      GBC / ABI / BioRad / Qiagen
    • Cat. No.
      4HBPA2
    • Package Size
      48 TESTS / KIT
    • Linear Range
      10 IU~2.0E+09 IU/mL for 0.5mL input
    • LOD
      9.01 IU/mL for 0.5mL input, 16 IU/mL for 0.2 mL input
    • LOQ
      10.0 IU/mL
    • Precision (CV%)
      2.00 (log10IU/mL)=19.24%: 4.30 (log10IU/mL)=2.69%; 6.30 (log10IU/mL)=2.14%
    • Genotype Detection
      A, B, C, D, E, G, wild types and mutants
    • Specimen Type
      Serum and plasma
    • Time to Result
      All processes including extraction within 3~4 hours (Manual or Automation)
    • Configuration
      Master Mix, Primer, Probe, Internal Control, 5 Quantification Standard
    • Standardization
      WHO International Standard for HBV DNA(97/746)
    • Certification
      TFDA / CE

    GB HCV RealQuant® PCR Kit

    An in-vitro PCR kit for the quantitation of Hepatitis C virus (HCV) RNA in human plasma or serum from HCV-infected individuals.

      GB HCV RealQuant® PCR Kit– Product Details

      An in-vitro PCR kit for the quantitation of Hepatitis C virus (HCV) RNA in human plasma or serum from HCV-infected individuals.
      • Product Name
        GB HCV RealQuant® PCR
      • Platform
        GBC / ABI / BioRad / Qiagen
      • Cat. No.
        4HCPA2
      • Package Size
        48 TESTS / KIT
      • Linear Range
        20~1.0E+08 IU/mL
      • LOD
        37.28 IU/mL (95% CI 24.97~97.54 IU/mL)
      • Precision (CV%)
        2.00 (Log IU/mL)=8.3%; 4.30 (Log IU/mL)=4.5%; 6.30(Log IU/mL)=3.5%
      • Genotype Detection
        Genotype 1-6
      • Specimen Type
        Serum or Plasma (EDTA as anti-coagulation substance is recommended)
      • Time to Result
        All processes including extraction within 3~4 hours (Manual or Automatic)
      • Configuration
        Master Mix, SR, Primer, Probe, Internal Control, Positive Control, 5 Quantification Standards
      • Standardization
        3rd WHO International Standard for HCV RNA (NIBSC, 06/100)
      • Certification
        TFDA

      GB HER2 RealEx™ PCR Kit

      GB HER2 RealEx™ PCR utilizes One-Step qRT-PCR technology to detect HER2 RNA expression in various types of human breast cancer tissues, including FFPE, OCT, and fresh frozen tissues.

        GB HER2 RealEx™ PCR Kit– Product Details

        GB HER2 RealEx™ PCR utilizes One-Step qRT-PCR technology to detect HER2 RNA expression in various types of human breast cancer tissues, including FFPE, OCT, and fresh frozen tissues.
        • Product Name
          GB HER2 RealEx™ PCR Kit
        • Format
          PLATE
        • Cat. No.
          4HEPA2
        • Package Size
          48 TESTS / KIT
        • Time to Result
          1.5~2 hr (not include extraction)
        • Specificity
          88.89%
        • sensitivity
          90.00%
        • Precision (CV)
          1.4-12.6%
        • Linear Range
          5.4~5.4*10^8 copies/uL
        • Time to Result
          1.5~2 hr (not include extraction)
        • Method
          qRT-PCR
        • Principle
          TaqMan Probe qRT-PCR
        • Fluorescence Dye
          FAM
        • Platform
          Qiagen Roter-Gene Q (Recommended)
        • Sample type
          FFPE, OCT & FF
        • Sample amount
          50ng total RNA
        • Shelf Life
          8 Months
        • Certification
          Research Use Only

        GB Master Mix (5mL)

        One-Step GBC qPCR TaqMan-DNA Master Mixture provides buffer system for real-time quantitative (qRT-PCR) in a convenient format that is compatible with standard qPCR cycling conditions.

        GB Master Mix (5mL)– Product Details

        One-Step GBC qPCR TaqMan-DNA Master Mixture provides buffer system for real-time quantitative (qRT-PCR) in a convenient format that is compatible with standard qPCR cycling conditions.
        • Product Name
          GB Master Mix (5mL)
        • Platform
          GBC / ABI / BioRad / Qiagen
        • Cat. No.
          3P092PBQ
        • Package Size
          5 mL / bottle
        • Certification
          Research Use Only
        • Storage Methods
          Keep away from lightStored at -20℃

        Genesis™ M1200

        With the flexibility of processing 1-12 samples per run, it is tailor-made to fit small clinics and early stage laboratories. By occupying minimal counter space and greatly reducing technician manhours, this series allows organizations to operate facilities in a much more cost effective fashion.

        Genesis™ M1200– Product Details

        With the flexibility of processing 1-12 samples per run, it is tailor-made to fit small clinics and early stage laboratories. By occupying minimal counter space and greatly reducing technician manhours, this series allows organizations to operate facilities in a much more cost effective fashion.
        • Product Name
          GB GENESIS™™ M1200
        • Type
          DNA/RNA Extraction System
        • Model
          M1200
        • Cat.No.
          SMZOP01001
        • Processing Capability
          1-12 samples/run
        • Sample Volume
          100-1000μl
        • Dimentions
          W48cm*D70cm*H52cm
        • Weight
          43kgs
        • Safety
          CE IVD

        Genesis™ M2400

        GB GENESIS™ M2400 has the flexibility of processing 1-24 samples per run, making it ideal for labratories requiring nucleic acid purification of small to middle sample throughputs.

          Genesis™ M2400– Product Details

          GB GENESIS™ M2400 has the flexibility of processing 1-24 samples per run, making it ideal for labratories requiring nucleic acid purification of small to middle sample throughputs.
          • Product Name
            GB GENESIS™™ M2400
          • Type
            DNA/RNA Extraction System
          • Model
            M1200
          • Cat.No.
            SMZOP01003
          • Processing Capability
            1-24 samples/run
          • Sample Volume
            100-1000μl
          • Dimentions
            W90cm*D58cm*H54cm
          • Weight
            100kgs
          • Safety
            CE IVD

          Qiagen Rotor-Gene Q

          2/5 channel Real-Time PCR Analyzer certified to be used with GBC products.

          Qiagen Rotor-Gene Q– Product Details

          2/5 channel Real-Time PCR Analyzer certified to be used with GBC products.

            HIV Ag-Ab COMB

            For in-vitro qualitative detection and screening assay of HIV infection in human serum or plasma.

            HIV Ag-Ab COMB– Product Details

            For in-vitro qualitative detection and screening assay of HIV infection in human serum or plasma.
            • Product Name
              HIV Ag-Ab COMB
            • Specificity
              99.7%
            • Sensitivity
              100%
            • Format
              PLATE
            • Cat. No.
              S00454 (96 TEST/KIT)
              S00455 (192 TESTS/KIT)
              S00456 (480 TESTS/KIT)
            • Package Size
              96 TESTS / KIT (S00454)
              192 TESTS / KIT (S00455)
              480 TESTS / KIT (S00456)
            • Principle
              Enzyme Linked Immunosorbent Assay
            • Certification
              CE

            GB TempCard™/ Reader

            GB TempCard™ Temperature Recorder incorporates an innovative temperature sensor built inside this portable device. GB TempCard™ has been designed to endure hard damages yet still provide a fast reaction time.

              GB TempCard™/ Reader– Product Details

              GB TempCard™ Temperature Recorder incorporates an innovative temperature sensor built inside this portable device. GB TempCard™ has been designed to endure hard damages yet still provide a fast reaction time.
              • Type
                Temperature Recorder
              • Product Name
                GB TempCard™
              • Cat. No.
                S00351
              • Capacity
                8000 temperature readings (16Kbytes memory)
              • Frequency
                Adjustable, 30 seconds to several hours
              • Download Time
                Typically with full memory in less than 5 seconds depending on computer or readout device used
              • Environmental
                IP65
              • Battery
                3V Lithium
              • Life
                2~3 years on regular uses
              • Real Time Clock
                Installed with Real Time Clock;Rated accuracy ±25ppm @ 25°C (equiv to 2.5 seconds/day);Rated temperature coefficient is -0.034±0.006ppm/°C;(i.e typically +/- 0.00294seconds/day/°C)
              • Dimension
                86mm (L) x 55mm (W) x 8.6mm (H)
              • Weight
                35g
              • Case Material
                Polycarbonate
              • EMC Compliance
                Tested and complies with EC EMC directives(EN 50081-1:1992 & EN 61000-6-1:2001)
              • EN12380 Compliance
                Tested and complies to EN12830:1999 for transport, storage and distribution of chilled, frozen, deep frozen, quick-frozen food and others
              • Certification
                TFDA